Operation Manual / TPL73-B.. - 85-B11/ -B12
5 Maintenance / 5.4 Cleaning the compressor during operation
© Copyright 2018 . All rights reserved. HZTL2480_EN Revision D July 2018
5.4.1 Wet cleaning using external water-pressure vessel
(XC3)
In order to carry out a successful cleaning procedure that has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
w Engine load 25 ... 85%
w If the engine compartment temperature is less than 0°C during wet
cleaning of the compressor, precautionary measures must be taken
to prevent ice formation.
u Start cleaning cycle according to following description Wet cleaning
operation with XC3.
Operating procedure for compressor wet cleaning with XC3
Operating the water pres-
sure vessel
u The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
u Remove sealing plug (X).
u Fill vessel with required volume of clean water (see table Cleaning
parameters).
u Screw in sealing plug (X).
Page 63 / 151