- 83 -
000514AG
1. Set Time
Allows you to set the current date and time (not counting summer time)
2. Set Cash
This section of the menu allows you to set the name of the currency
and the value of 1 kWh of energy produced. Setting these parameters
correctly allows the actual earnings/savings achieved by the system to
be displayed.
• Currency: sets the desired currency (default is Euro)
• Val/KWh: indicates the cost/incentive for 1 kWh in the chosen currency
(default is 0.50).
3. Set RS485 Com
This section of the menu allows you to adjust the settings relating to the
RS485 communication serial line:
• Address: It allows you to set the address for serial communication of
the individual inverters connected to the RS485 line. The UP and DOWN
buttons scroll through the numerical scale. (The addresses that can be
assigned are 2 to 63).
• Protocol: It allows you to set the type of protocol to be used for the
RS485 line. The proprietary "Aurora (slave)" protocol or "ModBus RTU"
protocol can be selected.
• Parity: It allows you to set the Parity bit (None, Even, Odd).
• Baud Rate: It allows you to set the Baud Rate (2400/4800/9600/19200
/34800/57600/115200).
4. Country Select.
It allows you to modify the grid standard (this option can be selected
before the inverter is switched on) within 24 hours while the inverter is
operating.
• Set Std: allows you to set the required grid standard.
• Residual Time: indicates the time remaining until the "Country Select"
feature is blocked.
• Reset Country: Unlocks the grid standard selection (resets the 24
hours available for changing the grid standard).
5. New Password
This section of the menu allows you to change the settings menu pass-
word (default 0000).
We advise you to memorise the new password.
If the Password is lost you will not have access to the inverter, since there is no Reset function
for security reasons.