UNO-6.0-DM-TL-PLUS
Communication
Embedded Communication Interface Wireless
(5)
Optional Communication Interface RS485, Ethernet, Zigbee
(6)
Embedded Communication Protocol ModBus TCP (SunSpec)
Optional Communication protocol ModBus RTU (SunSpec) , Aurora Protocol
Commissioning tool Web User Interface, Display, Aurora Manger Lite
Firmware Update Capabilities Locally and remotely
Monitoring
Plant Portfolio Manager, Plant Viewer,
Plant Viewer for Mobile
(7)
Environmental
Ambient temperature range
-25...+60°C /-13...140°F
with derating above 45°C/113°F
Relative humidity 0...100 % condensing
Acoustic noise emission level 50 dBA @ 1 m
(10)
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 418 mm x 553 mm x 180 mm/16.5” x 21.8” x 7.1”
Weight 20.5 kg / 45.2 lb
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE, RCM
Safety and EMC standard
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2,
AS/NZS 3100, EN 61000-6-1, EN 61000-6-3,
EN 61000-3-11, EN 61000-3-12
Grid standard
(9)
(check your sales channel for availability)
CEI 0-21, DIN V VDE V 0126-1-1, G59/3, EN 50438 (not
for all national appendices), RD 1699, ITC-BT-40,
AS 4777, C10/11, IEC 61727, IEC 62116
1. Refer to the document “String inverter – Product Manual appendix” available at www.abb.com/solarinverters to know the brand
and the model of the quick t connector.
3. The AC voltage range may vary depending on specic country grid standard
4. The Frequency range may vary depending on specic country grid standard
5. As per IEEE 802.11 b/g/n standard
6. Availble for custom version only
7. Plant Viewer for Mobile availble remotely only, not for local commissioning
9. Further grid standard will be added, please refer to ABB Solar page for further details.
10. @ Pure sine wave condition.
Note. Features not specically listed in the present data sheet are not included in the product