VA Master FAM540 METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E 19
Table 5: Analoganzeiger ohne Grenzsignalgeber
Model FAM54xAx
Type of protection: constructional safety, dust explosion protection
Order
code*
Marking Terminals Electrical values T
amb
−20 °C to (−50 °C to )
Temp. class T
medium
Maximum
Insulation
A4, A9, B1 ATEX:
II 1/2 G Ex h T6 ... T1 Gb
II 2 D Ex h T85°C ... Tmedium Db
II 2 D Ex h tb IIIC T85°C ... Tmedium Db
IECEx:
Ex h tb IIIC T85°C ... Tmedium Db
n.a. n. a 70 °C T1 440 °C yes
70 °C T2 290 °C yes
70 °C T3 190 °C yes
70 °C T4 130 °C yes
70 °C T5 95 °C yes
70 °C T6 80°C yes
* Order code ‘Explosion protection and approvals’ (versions 9, 10); refer to Ordering information in the data sheet on page 62.
Change from one to tw o columns
Operating instructions
Protection against electrostatic discharges
DANGER
Risk of explosion!
The painted surface of the device can store electrostatic
charges.
As a result, the housing can form an ignition source due to
electrostatic discharges in the following conditions:
• The device is operated in environments with a relative
humidity of ≤ 30 %.
• The painted surface of the device is thereby relatively free
from impurities such as dirt, dust or oil.
• Instructions on avoiding ignition in potentially explosive
environments due to electrostatic discharges in
accordance with PD CLC/TR 60079-32-1 and IEC TS 60079-
32-1 must be complied with!
Instructions on cleaning
The painted surface of the device must be cleaned only using a
moist cloth.