VA Master FAM540 METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E 19
Table 5: Analoganzeiger ohne Grenzsignalgeber
Model FAM54xAx
Type of protection: constructional safety, dust explosion protection
Order
code*
Marking Terminals Electrical values T
amb
20 °C to (50 °C to )
Temp. class T
medium
Maximum
Insulation
A4, A9, B1 ATEX:
II 1/2 G Ex h T6 ... T1 Gb
II 2 D Ex h T85°C ... Tmedium Db
II 2 D Ex h tb IIIC T85°C ... Tmedium Db
IECEx:
Ex h tb IIIC T85°C ... Tmedium Db
n.a. n. a 70 °C T1 440 °C yes
70 °C T2 290 °C yes
70 °C T3 190 °C yes
70 °C T4 130 °C yes
70 °C T5 95 °C yes
70 °C T6 80°C yes
* Order code ‘Explosion protection and approvals’ (versions 9, 10); refer to Ordering information in the data sheet on page 62.
Change from one to tw o columns
Operating instructions
Protection against electrostatic discharges
DANGER
Risk of explosion!
The painted surface of the device can store electrostatic
charges.
As a result, the housing can form an ignition source due to
electrostatic discharges in the following conditions:
The device is operated in environments with a relative
humidity of 30 %.
The painted surface of the device is thereby relatively free
from impurities such as dirt, dust or oil.
Instructions on avoiding ignition in potentially explosive
environments due to electrostatic discharges in
accordance with PD CLC/TR 60079-32-1 and IEC TS 60079-
32-1 must be complied with!
Instructions on cleaning
The painted surface of the device must be cleaned only using a
moist cloth.