Specification – Sensor
Functional specification
Temperature limitations
Ambient temperature
Remote transmitter –20 to 70 °C (–4 to 158 °F)
Integral transmitter –20 to 60 °C (–4 to 140 °F)
Process temperature See table below.
0.1 to 50 °C (32.2 to 122 °F)
OIML R49 T50 Approved
Medium temperature °C (°F)
Code Lining Flange material Minimum Maximum
FEF, FEW3 Hard rubber Carbon steel
Stainless steel
FEW1 PTFE Carbon steel
Stainless steel
FEW3 PTFE Carbon steel
Stainless steel
FEW3 Elastomer Carbon steel
Stainless steel
FEF, FER Elastomer Carbon steel
FEV Polypropylene
Pressure limitations
As flange rating
PN25 Max Process Temp 50 °C (122 °F)
PN40 Max Process Temp 40 °C (104 °F)
OIML / MID Approved Meters 16 bar (232 psi)
UL Fire Service approved meters 285 psi
Pressure equipment directive 97/23/EC
This product is applicable in networks for the supply,
distribution and discharge of water and associated
equipment and is therefore exempt.
IP rating
IP68 (NEMA 6) to 7 m (20 ft.) depth
Note. Not sizes DN10 to DN32 (3/8 – 11/4 in. NB)
IP67 (NEMA 4X) – DN10 to DN32 (3/8 – 1¼ in. NB)
Buriable (sensor only)
FEV, FEF and FEW – DN450 to 2400 (18 to 96 in. NB)
to 5 m (16 ft.) depth
Conductivity
>20 µS cm–1
Transmitter mounting
Integral (not FEF) or remote
Electrical connections
20 mm glands
½ in. NPT
20 mm armored glands
Sensor cable
ABB WaterMaster cable available in two forms –
standard and armored
Maximum length 200 m (660 ft.)
Suspended solids
Suspended solids percentage of process medium should
not exceed 6 % of total volume
Physical specification
Wetted parts
Electrode material
Stainless steel 316 L / 316 Ti
Super-austenitic steel
Hastelloy® C-22 and Hastelloy C4
(other electrode materials available on request)
Potential equalizing rings
Minimum of 1 recommended
Lining material / potable water approvals
Potable Water Approvals
Code Size Range Liner WRAS
WRAS
60°C
ACS DVGW NSF
AZ/
NZS
4020
PTFE
PTFE
Elastomer
Hard
rubber
NSF
approved
material
FEV
Poly-
propylene
FEF
Elastomer
FEF
Hard
rubber
NSF
approved
material
FER
Elastomer
*Size is dependent on flange specification
Lining protection plates
Not required
Installation conditions (recommended)
Straight pipe requirements
Upstream Downstream
FEW / FEF 5 x DN 2 x DN
FEV 5x DN 0 x DN
FER 0 x DN 0 x DN
Pressure loss
Negligible at Q3 All full bore meters
<0.25 bar (<3.62 psi) at Q3 FEV (DN40 to 200
[1½ to 8 in. NB])
<0.63 bar (<9.13 psi) at Q3 FER (DN40 to 600
[1½ to 24in. NB])