ABB Welcome
®
5.3 Pushbutton outdoor station with keypad module
The keypad module can be assembled with a
pushbutton outdoor station, and users can enter the
password to open the door.
Users can enter the system settings menu by using the
following steps. (Press # to confirm and * to cancel. The
default system password is 345678.)
1. Set the device as an outdoor station or a gate
station.
Outdoor station:
#* system password # =>
1 # => 1 #
Gate Station:
#* system password # =>
1 # => 2 #
2. Modify "system password"
#* system password # =>
2 # => Enter new password (6-8 characters) # => Enter the password again #
3. Modify "door open code"
#* system password # =>
3# => Enter new door open code (3-8 characters) # => Enter the code again #
4. Set the voice message
If the audio module with the speech synthesis function (M251024A-.) is assembled, the local language can be set.
#* system password # =>
4# => Press or to choose the language => #
5. Enable or disable access control function
Enable access control function:
#* system password # =>
5# => 1 #
Disable access control function:
#* system password # => 5# => 2 #