ABB Welcome
®
39
Reset to factory default
Function
Command
LED
Reset to factory
default
Disconnect the power supply.
Reconnect the power supply.
Within 60 seconds, long-press the
programbutton for 5 seconds.
Finish reset.
——
White
Red, green,
orange cycle
——
Technical specifications for round pushbutton module with IC orNFC:
Work frequency
13.56 MHz
Standard
ISO 14443A
Support card
MIFARE One S50/S70, etc.
Output format
Wiegand, 24-bit, 34-bit
Supported NFC devices
Most NFC mobile. (Not all; testing is needed before using this function.)