4. Open the housing. The detector now sends a tamper
signal to the alarm centre.
Idle time
The default idle time of the detector is set to one minute.
This function works as follows:
1. The detector recognises a noise and sends a signal to
the centre. The idle time now begins. The LED flashes
once per second in this time.
2. When the idle time has expired, the detector can then
detect the next noise and send a signal to the centre.
ABUS Security-Center GmbH & Co. KG, hereby declares
that the device with item number FUGB50000 complies with
the essential requirements and other relevant provisions of
Directive 1999/5/EG. The declaration of conformity can be
obtained from the following address:
ABUS Security-Center GmbH & Co. KG
Linker Kreuthweg 5
86444 Affing
GERMANY"