Technical data
16 | EN
4x screws with raised head for installation
1x manual
Technical data
Secvest Small Wireless Magnetic Contact
868 MHz narrow band receiver from ABUS
II (EN 50131-1 + A1:2009 Section 7)
Protection class, IP pro-
tection class
IP34 (internal spaces, in its installed state)
IP = international protection or ingress protection
3 = tools and wires
4 = splashing water
Non-condensing average relative humidity 75%
40 g (with battery)
30 g without battery, 10 g battery only
2 (EN 50131-1 + A1:2009 Section 6)
according to EN50131-2-6 Section 4.5
1 LED
trigger signalling, for infrared programming
Jumper to deactivate the front LED
Plug-in terminal
Type C (EN 50131-1 Section 9 and EN 50131-6 Section 4.1)
Power supply compliant with EN50131-1:2006+A1:2009 9.2 and
EN50131-6 if installed correctly together with Secvest FUAA50xxx.
Power consumption/en-
ergy consumption
3 µA standby current
35 mA max.
1x CR2 battery, 3V, lithium LiMn02
Replacement battery FU2990
Battery under voltage
threshold
2.4 V, ‘Flat battery’ fault at < 2.4 V
During operation the voltage provided by the battery is monitored. If
the voltage is below the lower threshold of 2.4 V, a fault report is
sent to the alarm control panel and the user is informed.