Assistance: Press 4+6 together. Keypad displays scrolling LEDs ( ) with fast pulse tone.
Fire: Press 7+9 together. Keypad displays scolling LEDs ( ) with slow pulse tone .
Panic: Press Ö and # together. All LEDs (PA) illuminate and a constant tone emits.
Buttons must be held down for two seconds for Hotkey Operation.
This option defaults to 0 (disabled).
Note: For important information on Ö and # key operation see the note in An
Introduction to Programming the Accord xpC.
Group 5 Option 5 Auto Omit Keypad
When enabled (set to 1) the keypad is omitted if 20 keys are pressed without a valid code
being entered, this does not include the # key. The keypad is omitted from the system for
10 minutes and affects all keypads on the system. Keypad auto omit is indicated by flashing
zone LEDs ( ) on the keypad.
A keypad auto omit may be cancelled by operating a zone programmed as Keyswitch.
This option defaults to 0 (disabled).
Group 5 Option 6 Bell Output
When set to 0 the Bell output is negative applied (positive removed).
When set to 1 the Bell output is negative removed (positive applied).
This option defaults to 0 (negative applied).
Group 5 Option 7 Alarm Trigger Output
When set to 0 the Alarm Trigger output is negative applied (positive removed).
When set to 1 the Alarm Trigger is negative removed (positive applied).
This option defaults to 0 (negative applied).
Note: Only valid when Alarm trigger Output (Group4 - Option 7) is set to 3.
Group 5 Option 8 System Reset for Day Tampers
This option determines how the system may be reset after a tamper condition that occurs
when the panel is unset and has four modes:
0. Customer.
1. Engineer.
2. Technistore.
3. Engineer or Technistore.
Set to 0 (Customer): User code resets the system after day tamper activations.
Set to 1 (Engineer): User code can cancel a day tamper activation but the engineer code
is required to reset the system.