IE1-1230-B February 2001
Group 8  Option 7 Communicate Verified Alarm
This option has two settings:
0. No (Verified Alarm comm disabled).
1. Yes (Verified Alarm Comm enabled).
This option defaults to 0 (Verified Alarm Comm disabled).
Group 8  Option 8 Communicate Battery Low and AC Mains Failure
This option has two settings:
0. No (Batt Low/AC Fail Comm disabled).
1. Yes (Batt Low/AC Fail Comm enabled).
This option defaults to 0 (Batt Low/AC Fail Comm disabled).
Note: A.C. mains failure is transmitted after a one hour delay.
Group 8  Option 9 Communicate Periodic Test Report
This option has four settings:
0. Periodic Test Report Comm disabled.
1. Periodic Test Report Comm enabled24 hr test period.
2. Periodic Test Report Comm enabled7 day test period.
3. Periodic Test Report Comm enabled31 day test period.
When enabled (set to 1, 2 or 3) , the time between periodic test signals is dependant on the
option selected.
This option defaults to 0 (Periodic Test Report Comm disabled).
System Programming  Group 9 Parameters
SNOITPOMETSYS
PUORGNOITPOTLUAFED
9.)seY=1,oN=0(senoZdettimOetacinummoC=1)0(
9.)seY=1,oN=0(langisteS/tesnUtrevnI=2)0(
9.)rebmunenoz=81,enoN=0(enozkconKelbuoD=3)0(
9.)seY=1,oN=0(timOenoZresU=4)1(
9.)seY=1,oN=0(teseR/tesnUnoslangiserotserdneS=5)1(
9.)seY=1,oN=0(dewollanoitaivedyrtnE=6)0(
9.)seY=1,oN=0(goltnevetnirP=7)0(
9)seY=1,oN=0(sgnittestluafedyrotcaF=8)0(
9.)seY=1,oN=0(noisreverawtfosweiV=9)0(
Table 3.14 System Parameters