44
programmed the system may be set by pressing the # key, then the 2 (Part Set) key. See
SECTION 3: Programming the Accord; Group 4  Option 8 Easy Set.
Night Set 3 ( )
To Night Set the system:
Enter your User Code then press the 3 (Night Set) key.
This starts the setting of the system using the Night Set zone programming. This
allows a sub-set of the system to be set.
The Day LED () will flash during the Exit Time.
To cancel the setting procedure press the Ö key.
When the system sets, two confirmation beeps are emitted by the keypad and
internal speaker; after this the Ö key does not function.
Note: The activation of the keypad buzzer and internal speaker are dependant on the
programming of Group 4  Option 4 Part Set Exit Warning.
Easy Set allows users to Night Set the system without entering a User Code. If Easy Set is
programmed you may set the system by pressing the # key, then the 3 (Night Set) key. See
SECTION 3: Programming the Accord; Group 4  Option 8 Easy Set.
Unsetting [4]
To Unset the system the user should go to the keypad via the agreed entry route and enter
their user code.
Unsetting After or During an Alarm
On the keypad the LED or zone number corresponding to the first zone to go into alarm
illuminates. Entering a User Code stops any alarm that is in progress. To reset the system
enter the User Code again. If set for engineer reset after an alarm, entering the Engineer
Code causes an Engineer Reset. If the system is set for a technistore reset after an alarm,
all LEDs will illumniate for 1.5 seconds or the CE message will appear followed by the
zone number (Icon Keypad). All keypads will then display the 5 digit technistore code,
one digit at a time (each digit corresponds to an illuminated LED on the LED keypad).
Enter this code at the monitoring station to obtain an anticode which when entered causes
Technistore reset is overridden if there is a comms fail.
Note: The user code cannot reset the system after an alarm condition if Group 5 
Option 3 (Engineer Reset for Alarms) has been programmed for Engineer
Reset or Technistore Reset. .
Engineer Setting and Unsetting
The Engineer Code can be used to set the system (Full, Part or Night). It can only be used
to unset the system when it was previously used to set it.
Testing the System 5 ( )
To Test the zones and outputs on the system enter a valid code then press the 5 ( ) key.