Sample Type | Whole blood |
---|---|
Connectivity | RS-232 serial port |
Measurement Range (pO2) | 0-800 mmHg |
Measurement Range (sO2) | 0-100% |
Power Supply | 100-240 VAC, 50/60 Hz |
Measured Parameters | pO2, sO2 |
Calculated Parameters | O2 Saturation |
Sample Volume | 100 µL |
Display | LCD |
Accuracy (sO2) | ± 1% |
Response Time | 10 seconds |
Accuracy (pO2) | ±3 mmHg or ±3% (whichever is greater) |
Details the device's purpose and applications for blood oximetry.
Explains the measurement process, calculations, and automatic reporting features.
Outlines critical safety instructions, warnings, and precautions for instrument use.
Discusses constraints and considerations during instrument operation and test interpretation.
Describes the components and functions of the instrument's front panel, including display and keypad.
Details the purpose and functionality of each key on the AVOXimeter 4000 keypad.
Outlines the main menus, submenus, and commands for navigating the instrument's interface.
Explains the design, use, and handling precautions for the single-use test cuvettes.
Lists detailed technical specifications including size, weight, power, and performance ranges.
Provides the accuracy and precision specifications for total hemoglobin and saturation measurements.
Lists substances that may interfere with measurements and their effect on results.
Explains the factory calibration and user-required calibration steps for cuvette code and Hüfner's number.
Instructions for unpacking the instrument and inspecting components for damage upon receipt.
Lists all items included in the AVOXimeter 4000 package.
Step-by-step guide for charging the instrument's internal battery before first use.
Procedures for configuring instrument settings like display, units, date, and time.
Procedures for setting the current date and time on the instrument.
Options for enabling or disabling the entry of User IDs and Patient IDs for test tracking.
Instructions to set a custom Hüfner's number for oxygen content calculations.
Procedure for entering the cuvette calibration code to ensure accurate measurements.
Steps for powering on the instrument and its initial self-tests.
Guidelines for collecting and preparing whole blood samples for analysis using cuvettes.
Detailed procedure for performing a test on a patient sample using the AVOXimeter 4000.
Overview of storing, reviewing, printing, and transferring test data.
Methods for safely powering down the AVOXimeter 4000 instrument.
Guide for using optical filters to verify instrument calibration and optics.
Procedures for performing quality control tests using liquid control materials.
Procedure for entering the lot number of cuvettes for accurate measurement calibration.
Steps to verify the instrument's internal temperature against a calibrated thermometer.
Detailed instructions for disassembling and cleaning the optical detector assembly.
Step-by-step guide for safely replacing the instrument's internal battery.
Information regarding the instrument's warranty terms, limitations, and service policies.
Information on the instrument's electromagnetic emissions and compliance with standards.
Details on the instrument's immunity to electromagnetic disturbances and recommended environments.