Section
4:
fnstallation
-
2o3o-0MA
I nstal lation
Req
u irements
Installation site
must
meet
specified
requirements to
ensure
proper
nnachine
operation.
Foot
PrinVDimensions
23.4"W
x 34.66"H x25.25"D
(23.48cm
x 64.31cm
x 91.49cm)
Weight
245tb
(11
1 .13k9)
Counter Space
36"Wx
42"Hx29'D
(91
.44cm
x 106.68cm x rz3.66cmlf
Electrical
Located
within
5
feet of Machine
Sinqle
Phase:
200-240
VAC, 30
AMP Dedicated Circuit
NEMA
L14-30
Receptacle
Three
Phase:
200-240
VAC, 20 AMP, Three
Phase Dedicated Circuit
NEMA
L15-30 Receptacle
Hiqh
Leq:
200-240
VAC, 30 AMP, High
Leg Dedicated Circuit
International
Machines are
shipped without a
power
plug.
Plug
must
be
attached
at the time of
installatircn and
nreet
with
all
local electrical codes.
Water
Minimum:
30
psi,
Maximum 100
psi
2Sgallons
per
hour
Cold
Water
source with
Female
%"
NPT fitting with shutoff
valve
Located
within
5
feet of Machine
A fresh
water bypass
is required for sites
withr
a
Revense
Osmoses
Filter System.
Water Treatment
System
All Machines
are shipped
with a Everpure62Cl00
grain
water
treatment
system
which includes a carbon filter cartriclge
and
water softener
cartridge
25"Hx
11"Wx 5.25'D
Drain
Connection
for
3/o"
Drain
Hose
lndirect
Drain Required
Located
within 5 feet of
Machine
4-2
Acorto 2000rs/i Technical Support