Application Information AWM-G-2009
The exact length of pipe protruding from the face of the are die is determined by the aring tool. The table
showsthe use of an imperial die and riged die.
PIPE Ø, D (mm)
A(mm)
IMPERIAL DIE RIGED DIE
6.35 (1/4”) 1.3 0.7
9.52 (3/8”) 1.6 1
12.7 (1/2”) 1.9 1.3
15.88 (5/8”) 2.2 1.7
Fix the pipe rmly on the are die. Match the centers of both the are die and the aring punch, and tighten aring
punch fully.
INSTALLATION OF SEPARATE ORIFICE KIT AT OUTDOOR
i) Outdoor Unit Installation Space Is Wide Enough
Directly connect the “Female” nut of ori ce pipe to
the liquid pipe.
Orifice Pipe
Liquid Pipe
Flare the liquid pipe and connect it to the “Male”
joint of the ori ce pipe.