710-00039.1
3)
Battery Cables Inspection
Regularly inspect the DC cables for wear. If the DC cables or connectors become worn or damaged, they
should be immediately replaced with a cable of the same rating by qualified personnel. Inspect the
connector housing and make sure there is no damage. Inspect the tips of the battery connector for signs of
pitting due to arcing. Replace the tips as needed. Check the torque lines inside the charger. If needed,
make sure the torque is around 21 Ft-Lbs. (+0 /- 10%)
IMPORTANT NOTE:
Please Refer to doc 710-00037 Quantum GSE Maintenance
Manual for more instructions on the Maintenance of the GSE