3 ADAM PUMPS • DI - FLOW IN LINE
1.6 HARMFUL EMISSIONS
Both steam emission and noise emission are
negligible.
1.7 FIRE PREVENTIONFIRE PREVENTION
In case of fire, never use water, but use extin-
guishing powders charged with CO
2
only. Ex-
tinguishers should be kept near to the meter.
Combustion of paints and plastic parts may
produce toxic emissions: use the normal pre-
cautions in case of fire (always refer to the se-
curity supervisor of the place of installation).
2. PRELIMINARY OPERATIONS
2.1 2.1 PRODUCT AND MANUFACTURER
IDENTIFICATION DATA
Name and address of the manufacturer::
ADAM PUMPS SpA
Via della Resistenza 46/48
41011 Campogalliano (Modena) - Italy
Machine identification: Contalitri ussimetro
Models: DI FLOW IN LINE Gasolio, DI FLOW IN
LINE AddBlu.
2.2 PRODUCT DESCRIPTION
THE In-Line digital flowmeter is a device with a
turbine to accurately measure fluids with low vi-
scosity. It could be installed on piping or on mobile
installation, generally close to the nozzle.
The display has 6 digits and two buttons:
R(RESET) and T(TOTAL) , allowing to visualize
multiple data:
Visualize the liquid served at each transaction
-”Partial
Visualize the total quantity served during a
period ”Total Period
Visualize the total quantity transferred during its
life “Total
visualize calculated tank stock level (initial stock
level encoder manually) “Stock
Set a low stock alarm ”Alert
Visualize instantaneous ow rate
Scroll between last 5 transactions with possibili-
ty of making sub-totals
Calibrate the device for higher accuracy
Modify the unit of measure choosing between
Litre, Gallon, Pint, Quart of Custom (configured by
the customer).
For major information about these option refer to
the appropriate paragraph.
2.3 AUTHORIZED & FORBIDDEN USE
The owmeter can be used with differentuids
depending of purchased version:
1-DI FLOW IN LINE Diesel (black meter body)
Diesel
Kerosene (for heating)
Solvents
Anti-freeze
Light oils: max cinematic viscosity = 300 cSt
2-Di FLOW IN LINE AdBlue® (blue meter body)
AdBlu
Aus 32
Water
THE METER IS NOT COMPATIBLE with other
liquids and particularly not compatible with ga-
soline, gas, alcohol and hydrochloric acid.
If in doubt about the compatibility of a specific
fluid, contact the supplier of fluid to check for any
adverse reactions to the wetted materials in the
parts list.
2.4 TRANSPORT AND PACKAGE CONTENT
Due to its lightweight and compact design, the
unit can easily be unpacked and transported
by hand. Inspect the package and the product
for damage. Report immediately any damage
remediation. When opening the package, make When opening the package, make
sure the meter is in the box as well as the CD
containing its manuals. If it is not the case, call
your supplier immediately..
3. INSTALLATION AND USE
3.1 DISPLAY ORIENTATION
The meter is supplied with a calibration carried
out for liquid diesel at 20 °C. Calibration is
required when metering a different fluid, after
disassembly, at different temperature or after
significant wear. A proving container or a con-
tainer of KNOWN volume will be needed for the
calibration procedure. It is possible to invert theIt is possible to invert the
flow direction using following steps:
1. Remove the 4 screws from the back of the
meter
2. Rotate the meter body by 18
3. Reposition the body on the cover taking care of
not squeezing wires.
4. Screw the 4 screws to tighten the body to the
cover.