3.5.3 SELECTING UNIT OF MEASURE
The system has 4 standard units of measure (Litre
- US Gallon - Quarts & Pint) plus oneCustom
unit that can be configured by the user. To select
the unit, do as follows:
1. Start from “Partialscreen, to do this do not
press buttons for 10 seconds.
2. press to enter in “unit of measuremode,
the messageUnitwill be displayed
3. press to confirm
4. press to scroll between unit:
“litres”- “us-gal–“quartspints”custom”
5. press to confirm.
CUSTOM UNIT OF MEASURE
Default factory setting is decalitre (1/10 litre). This
value can be configured as follows:
1.Repeat operations 1 to 5 from paragraph 3.5.3
“Selecting unit of measure”.
2.Once the choice of “custom” has been confir-
med pressing button, the meter will propose
the default value blinking 0.100
3.Increase or decrease this value with and
button until you reach the desired value taking into
account that reference unit is the litre.
4. Once the correct value is displayed wait 10
seconds, the meter will save the value and return
toPartialscreen.
3.5.2 INSTANTANEOUS FLOW RATE
The device is capable of showing the instanta-
neousow rate during a transaction. To visualize
the ow rate press and maintain button during
transaction.
With this new calibration last transaction as well as
last 5 in history will be adapted to new calibration.
TOTAL and TOTAL PERIOD will remain unchan-
ged.
3.5.4 BUTTONS COMBINATIONS:
Starting fromPartial” screen:
(see table page 9)