INSTALLATION INSTRUCTIONS FOR
IP44 ILLUMINATED MIRRORS
Before installing this product pay special attention to these instructions. It is recommended
that this product is installed by a qualified electrician and current building regulations.
These products can safely be fitted into Zone 2. See lighting regulations diagram.
Prior to commencing work isolate the power supply cable at the fuse box.
Check that there are no other concealed cables or pipe work in the intended installation area
(check the entire area).
The mirror is mounted on the wall by means of two fixing screws.
Make sure that it is at the correct height and level. Using a suitable marker through the fixing
holes mark the position of the holes on the wall.
Using the correct size drill bit for the wall fixing (please note that for certain wall types i.e.
plasterboard walls, the wall fixings supplied are not recommended) drill holes in the marked
locations. Place the rawl plugs into the holes. Feed the supply through the central rubber
grommet, position the back plate and secure using the correct fixings (the rubber washers
provided must be used to ensure no water can penetrate into the fitting).
Connnect the supply cable to the connector block as shown in the wiring diagram. Ensure the
conductors are fully inserted into the terminals and no loose wire strands are protruding. fully
tighten the screws on the terminals making sure that the screw clamps onto the conductor and
not the insulation.
Fix the mirror to the wall.
Ensure that the correct type and wattage bulb are always used. (see Luminaire for details).
1.
2.
3.
4.
5.
6.
7.
8.
Shelf fixing (selected models only).
To fix glass shelf to mirror attach the metal support arms to the bottom of the mirror frame using
the screws provided. (the rubber washer supplied must be used to ensure that IP44 is
maintained). Place the glass shelf and secure with the screws located underneath the metal
support arm.
Cleaning Instructions
In order to maintain the quality finish of this product please do not use any abrasives or solvents
when cleaning this product. Use only a damp cloth for cleaning this product.
Do not allow water to stand on any part of the mirror.
Please clean any spillage that may affect the quality of the finish as described above.
Question and Answer IconNeed help?

Do you have a question about the Adema Saniclass Circle SW108324 and is the answer not in the manual?

Overview

This document provides installation and operation instructions for Saniclass Adema IP44 Illuminated Mirrors.

Function Description

The Saniclass Adema IP44 Illuminated Mirror is designed for bathroom use, featuring an IP44 rating for protection against water splashes. It includes LED backlighting and a heated de-mister pad to prevent fogging. The mirror is equipped with an IR sensor for controlling its functions.

Important Technical Specifications

  • IP Rating: IP44, indicating protection against solid objects larger than 1mm and water splashes from any direction.
  • Installation Zone: Suitable for installation in Zone 2 of a bathroom (refer to lighting regulations diagram for specific zones).
  • Power Supply: Requires connection to a mains electrical supply.
  • Mounting: Wall-mounted using two fixing screws.
  • Bulb Type: Specific bulb type and wattage must be used as detailed in the luminaire specifications (not provided in this excerpt).
  • Demister Pad: Heats the mirror surface above room temperature to remove mist.
  • IR Sensor: Allows for touchless control of LED color, light on/off, and demister on/off. When lights are on, the sensor can also adjust light brightness.

Usage Features

  • Touchless Control: The IR sensor allows users to wave their hands in front of it to change LED color, turn lights on/off, and control the demister.
  • Brightness Adjustment: When the lights are on, placing hands in front of the sensor can change the brightness of the light.
  • De-misting: The integrated de-mister pad automatically heats the mirror surface to prevent fogging, ensuring a clear reflection after showers or baths.
  • Shelf Fixing (Selected Models Only): For models with a glass shelf, metal support arms attach to the bottom of the mirror frame. A rubber washer must be used during shelf installation to maintain the IP44 rating.

Installation Steps

  1. Isolate Power: Before starting, isolate the power supply at the fuse box.
  2. Check Installation Area: Ensure no concealed cables or pipework are in the intended installation area.
  3. Mark Fixing Holes: Position the mirror at the desired height and level, then mark the positions of the two fixing holes on the wall using a suitable marker.
  4. Drill Holes: Drill holes at the marked locations using the correct size drill bit for the wall fixing. Note that for certain wall types (e.g., plasterboard), the supplied wall fixings may not be suitable.
  5. Insert Rawl Plugs: Place the rawl plugs into the drilled holes.
  6. Feed Supply Cable: Feed the electrical supply cable through the central rubber grommet on the mirror's back plate.
  7. Secure Back Plate: Position the back plate and secure it using the correct fixings. Rubber washers provided must be used to prevent water penetration and maintain the IP44 rating.
  8. Connect Supply Cable: Connect the supply cable to the connector block as shown in the wiring diagram. Ensure conductors are fully inserted, with no loose wire strands, and tighten screws securely onto the conductor (not the insulation).
  9. Fix Mirror to Wall: Secure the mirror to the wall.
  10. Bulb Check: Ensure the correct type and wattage bulb are used (refer to luminaire details).
  11. Minimum Distance: Install the mirror at least 15 cm away from the basin.

Electrical Wiring

The wiring diagram shows connections from the LED Mirror to the Main Supply:

  • Brown (LED Mirror) connects to live (Main Supply), which can be Brown/Red/Black.
  • Yellow/Green (LED Mirror) connects to earth (Main Supply), which can be Yellow/Green/Green.
  • Blue (LED Mirror) connects to neutral (Main Supply), which can be Blue/Black/White.
  • Ensure all conductors are fully inserted into terminals and screws are tightened onto the conductor, not the insulation.

Maintenance Features

  • Cleaning Instructions:
    • Do not use any abrasives or solvents when cleaning the product to maintain its quality finish.
    • Use only a damp cloth for cleaning.
    • Do not allow water to stand on any part of the mirror.
    • Clean any spillage immediately to prevent damage to the finish.
  • Special Care: While the finish is durable, harsh abrasives and cleaning pads can damage it. For cleaning, use a light, non-abrasive cleaning solution or cleaning polish.
  • Safety Warning: Always switch off the electrical supply at the mains during installation and maintenance.
  • Professional Installation: Installation and connection to electric wiring must be done by a professional electrician in compliance with local requirements for electrical installations.
  • No Modifications: Never modify the construction or add parts not offered as spare parts or accessories by the manufacturer. Unauthorized modifications can lead to weak mounting and the risk of parts falling from the wall.

Adema Saniclass Circle SW108324 Specifications

General IconGeneral
BrandAdema
ModelSaniclass Circle SW108324
CategoryPersonal Care Products
LanguageEnglish