9. SPECIFICATION:
MODEL
Micro PC 300 Micro PC 600
Internal UPS
(Hi Frequency)
CAPACITY (Computer Load) 300VA / 180W 400VA / 240W
INPUT Voltage 100V/110V/115V/220V/230V/240V ± 15%
Frequency 50Hz/60Hz Auto detect
OUTPUT Voltage 100V/110V/115V/220V/230V/240V ±5% for Back-up Mode
Frequency 50Hz or 60Hz ± 0.1Hz
Wave Form Simulated Pseudo Sine Wave
Runtime of one set of P.C.
(Including 15” LCD monitor)
10 minutes Typical. 30 minutes Typical.
TRANSFER TIME 4ms Typical.
BATTERY Maintenance Free
Lead-Acid Ni-MH
Voltage/Capacity 6V 3Ah x 2pcs 1.2V 3.5Ah x 15pcs
Recharge Time Approx. 8 hrs to 90% Approx. 21 hrs to 90%
LED/ALARM INDICATION
Normal/In charge GRN LED, No Beep.
Back up / Abnormal Input Voltage RED LED Flashing, 2 Beeps / 4 sec.
Power Saving (When No Load) RED LED Flashing,1 Beep / 4 sec. (Auto off in 30 sec.)
Low Battery RED LED Flashing, 4 Beeps / sec.
Battery Replacement RED LED Flashing, 8 Beeps/ sec.
Over Load/Fault RED LED Flashing, Continuous Beep.
Abnormal Input Frequency (Back up) RED LED Flashing, No Beep.
OPERATION TEMP. 0-40℃
OPERATION HUMIDITY 30-95% Non-Condensing
DIMENSIONS (L*H*W) 242 x 144 x 40(mm) 242 x 144 x 40(mm)
WEIGHT (N.W./G.W. KG) 3 .5/ 3.5 (kgs) 3.5 / 4.0 (kgs)
U P S
Uninterruptible Power System
User's Manual
INTERNAL TYPE
(Micro PC series)
Advanced Power Systems GmbH & Co. KG, Bayreuther Str. 6, D-91301 Forchheim
Phone: +49(0)9191-7005-0, Fax: +49(0)9191-7005-20, www.adpos-ups.de
Micro PC series Micro PC series