EasyManua.ls Logo

ADURO 9 - Page 19

ADURO 9
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
_______________________________________________________________________________________________________________________________
19
2.0 Installation of the wood burning stove
You are welcome to install your wood burning stove yourself but we strongly recommend that you consult your
chimney sweep before you begin the installation. Your dealer can also provide you with installation advice. It is
important to ensure that all local rules and regulations, including ones relating to national and European standards,
are complied with when installing this device.
Please note: You may not begin to use the wood burning stove until it has been inspected and approved by your
local chimney sweep.
2.1 Position of the stove/distance requirements
The new wood burning stove must be installed in a suitable and physically possible position. You need to be sure
that the position complies with local regulations. Distance requirements will only apply if the wood burning stove is
to be placed close to flammable materials. The Aduro 9 should be installed at a distance of 20 cm from flammable
materials at the rear and at a distance of 70 cm from the side. All furniture must be kept at least 80 cm away from
the front of the stove (see illustration below).
If the stove is positioned against a brick wall or other non-flammable material, there is no minimum distance
requirement. To facilitate cleaning and for the best use of the convection air, we recommend that you leave a
distance of approximately 510 cm to the wall. The Aduro 9 is built as a convection stove. This means that air from
the room circulates between the inner stove and the outer covering. As a result, the heated air is distributed evenly
throughout the room.
Behind stove
80
7070
20
Please note: that the Aduro 9 must be installed on a floor with the adequate load-bearing capacity. If the existing
construction does not meet this requirement, appropriate adaptation measures must be taken (e.g. a load-
distributing plate).
If the wood burning stove is to be placed close to flammable material, such as a wooden floor or carpet, it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the wood burning
stove, and 15 cm on each side.
2.2 Pipe connection
Aduro 9 leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back, remove
the round circle from the rear cover at the upper rear of the stove and then exchange the exhaust connector
(located on the top outlet above the stove) with the cover plate (that covers the rear outlet). The top outlet is
finished with the plate that lies in the ash drawer. A flue pipe with an internal diameter of 150 mm should be used
for Aduro stoves.