0-12 ADAM-5510/P31
Quick Start
0.4 Installation Example
Let’s follow the instructions below to integrate an Advantech
Paradym-31 demonstration and the ADAM-5510/P31.
1. Connect the host PC and the ADAM-5510/P31 as described in
section 0.2. Note that the COM port of the host PC and the COM1
port of the ADAM-5510/P31 must be connected by a cross-over
DB-9 cable. You may also connect the host PC and the COM2 (RS-
485) port of the ADAM-5510/P31 if the host PC has an RS-485 port.
2. Install one ADAM-5056 module in the ADAM-5510/P31
3. Run Advantech Paradym-31 under Windows NT 4.0.
4. Open the project file and select “DEMO”. The screen shown in
Figure 0-5 will appear.
5. Select “Build All and Run”. The ladder diagram demonstration will
be compiled and downloaded to the ADAM-5510/P31. The control
program will automatically execute on the ADAM-5510/P31.
6. You may select “Monitor” to monitor the execution of the control
program on the ADAM-5510/P31. See Figure 0-6.
7. This example project written in ladder diagram directs the ADAM-
5060 to turn on relays one by one. Appendix A gives a more
detailed explanation of this example.
Note: Please plug the Key pro of Paradym-31 on COM port of
host PC
0.5 ADAM-5510/P31 Remote I/O Function
0.5.1 Remote I/O Module Configuration
Before using Remote I/O Function, you have to configure
ADAM-4000 as following steps.
1. Connect ADAM-4000 modules to computer
2. Run ADAM utility to configure every ADAM-4000 module
individually