MANAGING SWITCH
129
RMON Alarm
The RMON Alarm page allows you to configure RMON statistics group and alarm groups.
To access this page, click Management > RMON > RMON Alarm.
Figure 4-102. Management > RMON > Rmon Alarm
The following table describes the items in the previous figure.
Table 4-100. Management > RMON > RMON Alarm
Item Description
Index Enter the index entry (1 to 65535) to define a specific Alarm Collection
history entry.
Interval Enter a value (1 to 2147483647) to define the interval value for the Alarm
Collection history.
Variable Enter the alarm variables to define the monitoring triggers.
Sample Type Enter the variable sample type.
Rising Threshold Enter the rising alarm threshold trigger.
Falling Threshold Enter the falling alarm threshold trigger.
Rising Event Index Enter the rising event index (1-65535) to define the alarm group.
Falling Event Index Enter the falling event index (1-65535) to define the alarm group.
Owner Enter the name of the owner of the RMON alarm group.
Apply Click Apply to save the values and update the screen.