The device is perfectly secure. It constantly monitors temperature values and several other electrical pa-
rameters to guarantee the user the highest level of performance and safety at all mes.
If during use an incorrect operang status is detected, there may be forced shutdown of the device with
the indicaon on the power level display, a ashing error code "Fx" or " hx ".
The dierent codes managed by the device are listed in the table below.
-
-
-
-
The ashing error code is displayed as long as the user has not stopped the unit himself and has not res-
tarted a new start, by using the SELECTION / ON key of the relevant replace.
If an error code remains permanently displayed despite several successive acknowledgment aempts,
contact the service department.
If error code F8 is displayed when the generator block is turned on, it indicates a problem with the fans.
Either there is no connecon (absence) of 1 or more fans, or there is reverse polarity, or there is overcon-
sumpon. You should contact the aer-sales service and report error F8.
Pending the verdict of the manufacturer, the user has the opportunity to inhibit the error F8 and use the
product in a degraded mode, unl the complete correcon of the problem.
EN