WARNING!
Be very careful when you use
open fire in the kitchen
environment. The
manufacturer declines any
responsibility in case of the
flame misuse.
The spark generator can
start automatically when you
switch on the mains, after
installation or a power cut. It
is normal.
In the absence of electricity
you can ignite the burner
manually.
Ignition of a hob burner with the
thermocouple
For manual ignition put the flame
near the burner. Push the knob for the
hob down and turn it
counterclockwise to the maximum gas
flow position
.
For integrated ignition on knob push
the knob for the hob down and turn it
counterclockwise to the maximum gas
flow position
.
Keep the knob for the hob pushed for
equal or less than 10 seconds to let the
thermocouple warm up. If not, the gas
supply is interrupted.
Adjust the flame after it is regular.
WARNING!
Do not keep the knob
pushed for more than 15
seconds. If the burner does
not light after 15 seconds,
release the knob, turn it into
the off position and try to
light the burner again after
minimum 1 minute.
If after some tries the burner
does not light, check if the
crown and its cap are in the
correct position.
If the burner accidentally
goes out, turn the knob to
the off position and try to
light the burner again after
minimum 1 minute.
5.2 Burner overview
WARNING!
Check that the heads
burners and the relative
burner caps are correctly
positioned in their housings.
A
B
D
C
A. Burner cap
B. Burner crown
C. Ignition candle
D. Thermocouple (if applicable)
5.3 Turning the burner off
To put the flame out, turn the knob to
the off position .
WARNING!
Always turn the flame down
or switch it off before you
remove the pans from the
burner.
www.aeg.com10