EasyManuals Logo

AERMEC NRW Series User Manual

AERMEC NRW Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11
CC
CC
AA
AA
RR
RR
AA
AA
TT
TT
TT
TT
EE
EE
RR
RR
II
II
SS
SS
TT
TT
II
II
CC
CC
HH
HH
EE
EE
FF
FF
EE
EE
AA
AA
TT
TT
UU
UU
RR
RR
EE
EE
SS
SS
nendo costante la temperatura di condensazione.
Ne è consigliabile l’impiego in tutte le installazioni per le
quali sia disponibile acqua di pozzo o di acquedotto.
Le versioni a pavimento sono predisposte per l’installazione
esterna di tale accessorio, utilizzando nella parte posteriore
il rubinetto collegato con la tubazione del gas in uscita dal
compressore.
Per ottenere i valori di resa con tale accessorio fare riferi-
mento ai valori relativi alle versioni motoevaporanti.
VPH - VALVOLA PRESSOSTATICA CON VALVOLA SOLE-
NOIDE DI BY-PASS -
Questo accessorio è previsto solo per le unità a pompa di
calore.
Nel funzionamento a freddo la valvola solenoide resta chiu-
sa, pertanto l’acqua passerà solo nel ramo sul quale è mon-
tata la pressostatica, che in tal modo potrà esplicare la sua
funzione. Nel funzionamento a caldo l’acqua attraversa
entrambi i rami.
Le versioni a pavimento sono predisposte per l’installazione
esterna di tale accessorio, utilizzando nella parte posteriore
il rubinetto collegato con la tubazione del gas in uscita dal
compressore ed il passacavo da utilizzare per il collega-
mento da eseguirsi secondo gli schemi elettrici.
Per ottenere i valori di resa, a freddo, con tale accessorio fare
riferimento ai valori relativi alle versioni motoevaporanti.
VT - SUPPORTI ANTIVIBRANTI -
Gruppo di quattro antivibranti da montare sotto il basamen-
to in lamiera, per le unità a pavimento, nei punti già predi-
sposti e servono ad attenuare le vibrazioni prodotte dal
compressore durante il suo funzionamento.
The accessory is externally installable on floor units, which
feature a valve connected to the compressor gas line.
To obtain the yield values with this accessory, refer to the
evaporator version values.
VPH - PRESSURE VALVE WITH BY-PASS SOLENOID
VALVE-
Accessory for heat pump units only.
During cooling applications, the solenoid valve remains clo-
sed; water passes exclusively through the section with the
pressure valve, which carries out normal operation. During
heating applications, water passes through both sections.
The accessory can be installed on the exterior of floor units,
which feature a valve connected to the compressor gas line
and the grommet for electrical connections made according
to the relative diagrams.
To obtain the yield values with this accessory, refer to the
evaporator version values.
VT - ANTIVIBRATION PADS -
Set of four vibration dampers for assembly beneath the base
(for floor units) in the prearranged fittings; dampen the
vibrations produced by the compressor.
Accessori disponibili • Available accessories
Mod. NRW PR PGS VP 6 VP 7 VP 8 VPH 6 VPH 7 VPH 8 VT 7
2 - 27 ✔✔
2 S - 27 S ✔✔
2 E - 27 E ✔✔
2 H - 27 H ✔✔
2 SH - 2 SH ✔✔
3 - 37 ✔✔
3 S - 37 S ✔✔
3 E - 37 E ✔✔
3 H - 37 H ✔✔
3 SH - 37 SH ✔✔
4 - 47 ✔✔
4 S - 47 S ✔✔
4 E - 47 E ✔✔
4 H - 47 H ✔✔
4 SH - 47 SH ✔✔
5 - 57 ✔✔✔
5 E - 57 E ✔✔
5 H - 57 H ✔✔
7 - 77 ✔✔✔
7 E - 77 E ✔✔
7 H - 77 H ✔✔
10 - 107 ✔✔
10 E - 107 E ✔✔
10 H - 107 H ✔✔
12 - 127 ✔✔
12 E - 127 E ✔✔
12 H - 127 H ✔✔ ✔✔
TABELLA DI COMPATIBILITÀ DEGLI ACCESSORI • ACCESSORIES COMPATIBILITY TABLE

Other manuals for AERMEC NRW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AERMEC NRW Series and is the answer not in the manual?

AERMEC NRW Series Specifications

General IconGeneral
BrandAERMEC
ModelNRW Series
CategoryChiller
LanguageEnglish

Related product manuals