Thermocouple signal cables are red/yellow twisted pairs. The colors listed refer
to the tag color on the wire pair. Green and yellow tags are only on 6 cylinder
instruments.
BLACK Cylinder 1 BLUE Cylinder 4
RED Cylinder 2 GREEN Cylinder 5
WHITE Cylinder 3 YELLOW Cylinder 6
If you have purchased a complete instrument and probe kit appropriate
connectors for interconnection of the signal wires and probe leads are provided.
If you have purchased only the instrument NO connectors are provided as there
is no way of determining what type of probes will be used. In this case the
installer is to provide the necessary connectors. WARNING! TSO and STC
certifications for this instrument will be void if it is used in conjunction with
NON-TSO’d thermocouples! See Specifications for requirements.
For installation of the complete kit, simply snap the connectors together for the
appropriate cylinders, slide the included heat shrink sleeves over the connection
and shrink to size. Take care in matching the correct color coded signal pair to
the correct cylinder.