EasyManua.ls Logo

AERZEN VML 310 - Event of Damage and Protection Information

Default Icon
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
V4-007 J EN
Originalbetriebsanleitung
16
of glowing embers!
Depending on the size and increased re protection regulations, a ame retardant
foam would be applied according to the order.
Information about the event of damage
If the unit produces an abnormal and/or unusual sound, the machine must be shut
down immediately using the EMERGENCY BREAK function.
The energy supply to the drive motor must be disconnected.
If the unit is blocked, the energy supply to the drive motor must be immediately dis-
connected.
The cause of malfunction must be determined.
Aerzener Service can be quickly at hand and provide expert troubleshooting for you.
The unit must not be taken into operation until it is properly functioning.
Information on operating/protecting
the compressor stage and the pressurised pipeline elements
The compressor stage is protected by oil pressure, discharge temperature and •
discharge pressure sensors. The sensors are connected to a fault signalling de-
vice/control at the factory. If the permissible operating parameters are exceeded
or undershot, the fault signalling device/control switches the drive motor off. In the
case of systems without a fault signalling device/control, the customer must install
an appropriate fail-safe control.
To ensure proper operation, the fault signalling device/control must be incorpora-•
ted into the drive motor safety chain in accordance with the circuit diagram. Plea-
se note that the fault signalling device/control and drive motor are fed from the
same
circuit, so that the motor cannot be operated without compressor protection.•
Property of American Airlines

Related product manuals