Agilent Technologies 8114A - User Manual

Agilent Technologies 8114A
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8114A and is the answer not in the manual?

Agilent Technologies 8114A Specifications

General IconGeneral
Output Impedance50 Ω
Number of Channels1
Pulse Width10 ns to 99.9 ms
ModesContinuous, Triggered
Trigger InputTTL

Summary

Installing the HP 8114 A

Power Requirements

Specifies the electrical power input needed for the instrument's operation.

Ventilation Requirements

Details necessary airflow and clearance for proper cooling and operation.

Operating Environment

Outlines the recommended ambient temperature and humidity for reliable performance.

Introducing the HP 8114 A

Faster Characterization and Test

Highlights features for efficient performance verification and analysis.

An Overview of the Frontpanel

Describes the layout and function of the instrument's front panel controls and display.

Controls

Explains how to use the front panel controls like cursors, knob, and softkeys for operation.

Operating Reference

Frontpanel Controls

Detailed guide on using softkeys, SHIFT/LOCAL, STORE/RECALL, DATA ENTRY, and MODIFY knob.

Connectors

Information on using EXT INPUT, TRIGGER OUT, and INHIBIT INPUT connectors.

HP 8114 A Programming Reference

Common Command Summary

Overview of SCPI commands for instrument control and configuration.

Status Model

Explanation of the instrument's status reporting system and registers.

Programming Trigger Modes

Details on setting up various trigger sources and modes for pulse generation.

Testing the HP 8114 A

Recommended Test Equipment and Accessories

Lists required external equipment and accessories for performing instrument tests.

Test 1: Period

Procedure and specifications for measuring the pulse period.

Test 2: Width

Procedure and specifications for measuring the pulse width.

Test 5: Jitter

Procedures for measuring various types of jitter (Period, Width).

Test 6: Amplitude

Procedures for measuring output amplitude under different conditions.

HP 8114 A Pulse Generator Specifications

General

Overview of environmental, safety, and power specifications for the instrument.

Output

Detailed specifications for the instrument's output characteristics, including amplitude and current.

Pulse Timing

Specifications related to pulse period, width, duty-cycle, and delay.

Trigger Modes

Specifications for different trigger modes like Continuous, Triggered, Gated, etc.