FLUSH CUTTING KIT INSTRUCTIONS (Model C16 only)
The ush cutting kit enables a ush cut blade (not included) to be
mounted to the machine which allows ush cuts to be made while
the outer blade guard is temporarily removed. The ush cut blade
may be left in place and the operator may return to standard cutting
simply by replacing the outer blade guard and securing with the 3
toggle latches. In this way, it is quick and convenient to switch
between standard and ush cutting mode. Or if desired, the ush
cutting blade and ange may be removed and the machine returned
to the standard conguration.
FLUSH CUTTING KIT LIST OF CONTENTS
1. Flush Cutting Flange
2. Socket Cap Arbor Bolt & Washer
3. Flat-Head Socket Cap Screws x 6
4. M5 L-Hex Wrench
5. M8 L-Hex Wrench
FLUSH CUTTING KIT ASSEMBLY
To mount the ush cutting kit, rst remove the standard arbor bolt, anges and blade .
1. Mount the ush cutting ange on the spindle and secure with the washer and socket cap arbor bolt.
Engage the arbor lock tighten the arbor bolt securely using the M8 L-hex wrench.
2. Mount the ush cut blade on the ange, align the holes and thread in the at-head socket cap screws.
Using the M5 L-hex wrench, tighten the screws evenly and diagonally.
FLUSH CUTTING KIT OPERATION
1. Remove the the water hose from water nozzle on the outer blade
guard and connect it to the alternate water nozzle on the inner
blade guard.
2. Remove the 6 screws securing the outer blade guard .
3. Unclip the 3 toggle latches and pop the loose hasps in the plastic
clips to prevent rattling.
4. Lift away the outer blade guard and keep in a safe place.
5. Once the ush cutting operation is completed, immediately
replace the outer blade guard and water hose.
WARNING: Always operate with the outer blade guard in place while performing standard cutting.
Never operate the saw with the outer blade guard removed except for ush cutting operations.
WARNING: Check the tightness of the mounting screws and arbor screw periodically.
WARNING: If any unusual vibration is felt in operation, stop immediately and nd the cause before