CAUTION
Do not apply power until engine oil temperature reaches 10°C.
WARNING
If the main rotor has not begun to rotate when gas producer (N1)
reaches 40%, abort the start by setting the ENG MODE switch to
OFF.
Engine N°1 and N°2 starters : Automatically deactivated when
N1 are 50%.
START and IGN legends auto-
matically suppressed.
Main hydraulic system : When the main rotor begins to
rotate, check rise in main hy-
draulic pressure.
Hydraulic utility system (normal and
emergency) : When accumulators are dis-
charged, as main rotor begins to
rotate, check pressure rise in
both systems and note the acti-
vation of MAIN UTIL CHRG
and EMER UTIL CHRG cau-
tion messages. Note both cau-
tion messages are suppressed
when systems are charged.
CAUTION
If MAIN UTIL CHRG and/or EMER UTIL CHRG caution
messages are not displayed during systems charging, abort and
correct trouble.
RFM A109E
R.A.I. Approved 2-27
Rev. 18