NOTE
When STARTER GEN IGN circuit breaker is out, the pertinent
ignition system is deactivated even though the Engine Control
Unit will provide the IGN message to the EDU.
Starter pushbutton (on engine power lever)
: Push and hold as necessary.
NOTE
To operate the starter it is also possible to utilize the ENG MODE
switch by setting IDLE.
CAUTION
Refer to Section 1 for engine starting limitations.
Gas producer (N1) : Note increasing.
Starter pushbutton : Release.
STARTER GEN IGN circuit breaker : In.
SYSTEMS CHECK
Engine and transmission oil : Pressure and temperature
within limits.
NOTE
The transmission oil pressure can be in the cautionary range
(yellow band) provided that the oil temperature is below 65°C.
SERVO (Main Hydraulic) : NORM, check. Make small
clockwise cyclic movements,
collective and pedals move-
ments. Pressure drops must be
equal for both systems (N°1
and N°2) and they should not
exceed 70 psi.
RFM A109E
R.A.I. Approved 2-29