EasyManua.ls Logo

AGUSTA A109E - Page 151

AGUSTA A109E
1418 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FUEL PUMP 1 : ON. FUEL PUMP 1 caution
message out and crossfeed
valve automatically closed (bar
vertical) and XFEED advisory
message suppressed.
FUEL PUMP 2 : OFF. Note fall in fuel pressure,
activation of FUEL PUMP 2
caution message on EDU 1,
automatic operation of cross-
feed valve (bar horizontal),
XFEED advisory message on
EDU 2 activated and conse-
quent new increase of fuel pres-
sure.
FUEL PUMP 1 : OFF. Note fall in fuel pressure,
activation of FUEL PUMP 1
and 2 caution messages, cross-
feed valve still open (bar hori-
zontal) and XFEED message
still present. Verify operation of
engine driven fuel pumps.
FUEL PUMP 1 and 2 : ON. FUEL PUMP 1 and 2 cau-
tion messages out and crossfeed
valve automatically closed (bar
vertical) and XFEED message
suppressed.
PITOT heat : ON (singly), check current
peak on loadmeter and PITOT 1
(2) HEAT advisory message
displayed; then OFF.
INVerter 1 : OFF. Check INV 1 caution
message displayed.
Check for proper reading (115
V) on bothAC systems on EDU
2 AUX display.
RFM A109E
R.A.I. Approved 2-31
UNMAINTAINED COPY