EDU message Fault condition Corrective action
IDS
Failure of the Inte-
grated Display System.
Possible degradation
in system function.
Try to identify the faulty
information and take the
pertinent corrective ac-
tion.
Refer to paragraph IN-
TEGRATED DISPLAY
SYSTEM FAILURE in
this Section.
DAU MISCMP-P
Some primary data
from one or both chan-
nels of Data Acquisi-
tion Unit invalid.
Possible degradation
in system function.
Try to identify the faulty
information and take the
pertinent corrective ac-
tion. Refer to paragraph
“INTEGRATED DIS-
PLAY SYSTEM FAIL-
URE” in this Section.
CAUTION LIGHT (YELLOW)
(If installed)
Panel wording Fault condition Corrective action
PITOT 1(2) FAIL
Associated pitot heater
failure
Exit pitot icing conditions
as soon as possible.
Switch the affected system
off.