CAUTION
Monitor engine start and if any of the following occurs:
- lightup is not obtained within 10 seconds of fuel on
- abnormal noises are heard
- TOT increases beyond start limit
- N1 or N2 increases beyond engine limits
- engine hangs (stagnation in N1 below 54%)
shutdown the engine by setting OFF the pertinent ENG MODE
switch.
Engine oil pressure : Check.
Engine starter : Automatically deactivated
when N1 is 50%.
START and IGN legends auto-
matically suppressed.
Engine power turbine speed (N2) : Check stabilized to idle speed
of 65% ± 1%.
NOTE
If the engine has been started directly to FLIGHT the N2 will
stabilize to 100%.
CROSS FEED switch : NORM (bar vertical).
Engine restart in flight with ECU inoperative (MANUAL mode)
Airspeed : 70 Kts.
ENG MODE switch (inoperative en-
gine) : OFF, check.