Engine power lever (inoperative en-
gine) : Move to FLIGHT.
Starting button : Push and hold.
START and IGN legends verti-
cally displayed beside N1 and
TOT scales on the EDU panel.
Gas producer (N1) : Note increasing.
Engine temperature (TOT) : Note increasing at light-off,
then keep it under control by
moving the engine power lever
as necessary to prevent exceed-
ing the TOT transient.
NOTE
If engine hangs below idle (less than 54% N1), slowly move
power lever forward beyond FLIGHT position, until the engine
accelerates, monitoring TOT, N1 and NR. If the engine does not
accelerate shutdown the engine by setting OFF the power lever
and release the starting button.
CAUTION
Monitor engine start and if any of the following occurs:
- lightup is not obtained within 10 seconds of fuel on
- abnormal noises are heard
- TOT increases beyond start limits
shutdown the engine by setting OFF the pertinent power lever and
release the starting button.
Starting button : Release when gas producer
(N1) reaches 50%.
START and IGN legends sup-
pressed.
RFM A109E
R.A.I. Approved 3-27
Rev. 11