Landing gear lever : DOWN EMERG (full down)
Check light sequence:
- Red light on (extension)
- Red light off
- Green light on (extended and
locked)
LANDING GEAR caution
message suppressed, if previ-
ously activated.
If the landing gear will not extend and/or lock also after the emergency procedure,
proceed to a hovering at a height sufficient for ground personnel to check the gear.
ELECTRICAL POWER FAILURE
(Helicopters not equipped with emergency bus)
EDU message Fault condition Refer to para.
# 1 (# 2) DC GEN cau-
tion
d.c. generator failure FAILURE OF A GEN-
ERATOR
BUS TIE caution Bus tie malfunction.
Check:
GEN BUS (1 or 2) switch
OFF
FAILURE OF GENERATOR
BUS#1OR#2
GEN BUS (1 and 2)
switches OFF
FAILURE OF BOTH
GENERATOR BUSSES
# 1 (# 2) DC GEN, BUS
TIE cautions.
d.c. generator and bus tie
malfunction.
Check:
GEN BUS # 2 switch
OFF
FAILURE OF GENERA-
TOR 1 AND GENERA-
TORBUS#2