CAUTION
Avoid to perform extreme manoeuvers.
Land as soon as practical.
EMERGENCY PROCEDURE FOR LIMIT OVERRIDE
PUSHBUTTON OPERATION
The engine is protected from limits exceeding through the engine limit
governing.
The engine limit governing is responsible for limiting measured engine
parameters.
The limit governing is set not to overcome the following limits:
Torque OEI 142%
Torque AEO 110%
TOT 930°C
N1 102.4%
In emergency condition the pilot may operate the LIM OVRD red pushbutton
located on the collective control to override the engine limit governing.
PROCEDURE
LIM OVRD pushbutton
(on collective control) : Press.
CAUTION
Limit override pushbutton operation is allowed for actual emer-
gency only.
EDU 2 : LIMIT OVRD ON advisory
message displayed.
RFM A109E
3-60 R.A.I. Approved
Rev. 11