SHUTDOWN
CAUTION
The rotor brake must be disengaged whenever the engines are
running.
Rotor brake : Apply below 40% rotor RPM.
POST FLIGHT CHECK
Rotor brake lever : Disengaged (full forward)
SECTION 3 - EMERGENCY AND MALFUNCTION
PROCEDURES
CAUTION MESSAGES (YELLOW)
EDU message Fault condition Corrective action
ROTOR BRK ON Rotor brake lever not in
OFF position.
Check rotor brake lever in
OFF position (full for-
ward). If message remains
on, land as soon as practi-
cal.
SECTION 4 - PERFORMANCE DATA
No change.
RFM A109E
APPENDIX 1
R.A.I. Approved Page 5 of 5
Rev. 11