FIRE
ENGINE FIRE IN FLIGHT
Procedure
HTR switch : OFF.
SHUT-OFF # 1 and # 2 switches : OFF.
MIX switch : OFF:
SMOKE IN CABIN, TOXIC FUMES, ETC.
HTR switch : OFF.
SHUT-OFF # 1 and # 2 switches : OFF.
MIX switch : OFF.
HEATER MALFUNCTION
If a malfunction in the bleed-air heater unit controls occurs disconnect the
system as follows:
HTR switch : OFF.
SHUT-OFF # 1 and # 2 switches : OFF.
MIX switch : OFF.
Proceed with flight, correct trouble prior to next flight.
RFM A109E
APPENDIX 6
R.A.I. Approved Page 7 of 18
UNMAINTAINED COPY