— -131 consists of an internal arrangement without any litter, eight seats
(including the pilot), panels at the upper side of lateral and aft walls for
medical devices, lights and a provision for the oxygen system.
—
-137/-173 in addition to the components listed for -119/-165 it includes
different passengers belts P/N AGU-001A and a supplementary fuel tank
P/N 109-0811-49, of 105 liters capacity (for version -137) and a supple-
mentary fuel tank P/N 109-0812-46, of 94 liters capacity (for version -173),
installed behind the aft passenger seat, RH side (refer to Appendix 8 for
Supplementary Fuel Tanks P/N 109-0811-49 and Appendix 36 for Supple-
mentary Fuel P/N 109-0812-46) of this manual.
— -143 in addition to the components listed for -119 it includes different
passengers belts P/N AGU-001A.
— -145 in addition to the components listed for -127 it includes different
passengers belts P/N AGU-001A.
— -163 as -183 but with passengers belts P/N AGU-001A.
— -183 as -173 but with oxygen system removed.
The E.M.S. comprises an intercommunication system for the patient attendants.
CAUTION
All medical equipment incorporating electronic devices must
satisfy the electromagnetic compatibility requirements.
NOTE
For the E.M.S. P/N 109-0811-70-113/-119/-137/-143/-163/-165/-
173/-179/-183, the electromagnetic compatibility has been veri-
fied with the following medical equipment:
- Lifepak 12 defibrillator plus monitor P/N VLP 12-02-000033 or
- Lifepak 12 defibrillator plus monitor P/N VLP 12-02-000602
- Oxylog 2000 pulmonary ventilator P/N 8413950
- Dialog 2000 monitor P/N 5706201
- Oxypac pulse oximeter P/N 2128578
- Syringe infusion pump IVAC P2000 P/N 2001FA2UGB0
- Medical suction unit 0B Minivac ASP 70170 P/N BF
RFM A109E
APPENDIX 10
Page 2 of 15 E.A.S.A Approved
Rev. 37