TURBINE OUTLET TEMPERATURE (TOT)
All engines operative (AEO)
Maximum continuous : 820°C
Takeoff (5 min) range : 820°C to 863°C
Maximum : 863°C
One engine inoperative (OEI)
Maximum continuous : 885°C
2.5 min range : 885°C to 930°C
Maximum : 930°C
Transient (20 sec) : 972°C
Starting (2 sec) : 875°C
ROTOR LIMITATIONS
NOTE
100% rotor speed corresponds to 384 RPM.
Power On (AEO)
Minimum : 99%
Continuous operation : 99 to 101%
Takeoff and landing (below 60 KIAS
and 1000 ft AGL) : 101 to 102%.
NOTE
During an instrumental approach procedure the use of 102% NR
is allowed up to 120 KIAS.
Maximum : 102%
RFM A109E
R.A.I. Approved 1-11
Rev. 2