One engine inoperative (OEI)
Maximum continuous : 124%
2.5 min : 142%
Transient (6 sec) : 156%
NOTE
The One Engine Inoperative (OEI) rating use is intended for
emergency use, when one engine becomes inoperative due to an
actual malfunction. OEI operations for maintenance or training
purposes shall be limited to the maximum continuous OEI power
rating.
NOTE
Transient must not be used intentionally. OEI transient may be
used only in case of real emergency, when one engine becomes
inoperative due to an actual malfunction.
FUEL SYSTEM LIMITATIONS
Fuel pressure
Cautionary range : 0 to 7 psi
Normal range : 7 to 25 psi
Maximum : 25 psi
Approved fuels
Type Specification
JET A ASTM D1655
JET A-1 ASTM D1655
JET A-2 ASTM D1655
JET B ASTM D1655
RFM A109E
R.A.I. Approved 1-13
Rev. 11