MAIN HYDRAULIC SYSTEM LIMITATIONS
FLUID PRESSURE
Minimum : 1200 psi
Cautionary range : 1200 to 1400 psi
Normal range : 1400 to 1550 psi
Maximum : 1550 psi
Approved fluids
Hydraulic fluid MIL-H-5606
WARNING
Operation of each hydraulic system must be checked before each
flight in accordance with Section 2 of this manual.
UTILITY HYDRAULIC SYSTEM LIMITATIONS
NORMAL SYSTEM FLUID PRESSURE
Minimum : 500 psi
Cautionary range : 500 to 1140 psi
Normal range : 1140 to 1550 psi
Maximum : 1550 psi
EMERGENCY SYSTEM FLUID PRESSURE
Minimum : 1140 psi
Maximum : 1550 psi
Approved fluids
Hydraulic fluid MIL-H-5606
RFM A109E
R.A.I. Approved 1-17