applications (s. man. 6.1). If only alarm values shall be printed at a cyclic
measuring point scan, the format Alarm must be set.
The output format is indicated in function baud rate ´BR´ by a letter between
the output channel ´U´ and the baud rate. The key M can be used to
successively select the following options.
Format Printout Display
List
measured values in a list
U 9 6 0 0 B
R
n Columns
measured values in columns
U n 9 6 0 0 B
R
t Spreadsheet
meas. values in spreadsheet format
U t 9 6 0 0 B
R
A Alarm
alarm values only, as a list
U A 9 6 0 0 B
R
as above without data cable:
save alarm values only
S A - - - - B
R
9.3 Manual Data Output
If the key START/STOP is not required for process control of the measurement, it
can also be used to provide function values, which have been selected with the
keys F1 or F2, or even data tables as output to a printer or computer. The other
functions (marked with *) can be either printed out using interface commands,
or via an additional trigger cable (accessory ZA 1000-ET, variant 3, see man.
6.10.9). This trigger cable is plugged into socket A2 and the outputs are
triggered using the external key.
Depending on the selected function the following printouts are available:
Function Ab Ke Printout
MEAS.VAL. *
Dim
M
12:34:00 01: +0023.5 °C
MAX VALUE
MH
F1
MAXIMUM VALUE: 01: +0020.0 °C
MIN VALUE
ML
F1
MINIMUM VALUE: 01: -0010.0 °C
MEMORY
MF
F1
MEMORY: - - - - s. 7.4.3
TIME CONSTANT
s
F1
TIMECONST: 10
AVERAGE VAL
*
AV
F1
AVG VALUE: 01: +0017.8 °C
COUNT
(all meas. values)
C F1 MS MEASVAL MAXVAL MINVAL AVGVAL COUNT
01:+0023.0 +0025.0 +0019.0 +0022.0 99999 s. man. 6.4.4
VOLUME FLOW
V
F1
VOLUME: 01: 00419 m3/h
PRINT CYCLE *
PC
F1
PRINT CYCLE: 00:06:00
TIME
TM
F1
TIME: 12:34:00
DATE
DA
F1
DATE: 01.02.99
RANGE
*
R
F2
01:NiCr +0123.4 -0012.0 +0000.0 °C 1.0000 E+0- - -
LIM. VAL. MAX
LH
F2
LIM VAL MAX: 01: -0100.0 °C
LIM. VAL. MIN
LL
F2
LIM VAL MIN: 01: +0020.0 °C
ZERO POINT
ZC
F2
ZERO POINT: 01: -0000.7 °C
SLOPE (GAIN)
SC
F2
SLOPE: 01: +1.0013
BASE
BA
F2
BASE VAL: 01: -0273.0 °C
FACTOR
FA
F2
FACTOR: 01: +1.0350E-1
EXPONENT
EX
F2
FACTOR: 01: +1.0350E-1
ALMEMO
2290-4 43
Digital Data Output