A: Light ON/OFF key: press this touch sensor to switch on or o the lights of the hood.
B: Motor ON/OFF key (4 speed): press this touch sensor to switch on the hood extractor fan
at the same speed as it was when last switched o. Use the „D“ and „C“ keys to vary
the speed (power) of extraction.
C: Decrease extraction speed (power) key: press this touch sensor to reduce the extraction
speed of the hood.
D: Increase extraction speed (power) key: press this touch sensor to increase the extraction
speed of the hood.
E: Timer key: irrespective of the extraction speed selected, touching the key will
activate the timer function for 5 minutes (during this phase a dot will ash on and o
on the display). To reset the timer operate the E motor key.
F: Filters reset key: touching this key will reset the metal anti-grease lter (1) saturation
and carbon lter replacement (2) warning. (1) After the hood has been operating for
40 hours, the “FG“or”G” symbol on the display will begin to ash, indicating the need
to clean the metal antigrease lters.
(2) After the hood has been operating for 120 hours, the “FC”or”C” symbol on the display will begin
to ash, indicating the need to clean the active carbon lters.
Automatic Sensor: tapping both C and “D keys at the same time will activate the Automatic Sensor”
function. This function, indicated with an A on the display, automatically sets the hood at the best
extraction speed, depending on the cooking going on. To return to manual operation, press “C” or
“D” button.
Note: 4 hours after the last key touch, the fan will automatically turn o.
All hoods with capacities exceeding 650 m3/h have the last timed speed; It lasts for 7 minutes,
after which it automatically returns to the last non-timed speed.