_NMEA 2000® RECEIVED PARAMETER GROUP_
PGN 065286 (0x0FF06)
Proprietary: Boot State Request
Single Frame: Yes Access Level: 0
Field
#
Name DD DF Type Resolution
Value Remark
1 Manufacturer Code DD172
DF52
11 bits 1 135 (decimal) Manufacturer Code for Airmar Technology.
2 Reserved bits DD001
DF52
2 bits 1 0x3 All bits set to logic "1"
3 Industry Group DD168
DF52
3 bits 1 4 (decimal) Industry Group for "Marine Industry".
4 Reserved bits DD001
DF52
48 bits 1 0xFFFFFFFFFFFF All bits set to logic "1"
Notes
When this destination global PGN is received by the PB200, the unit will respond by transmitting PGN 65285 (see). It is intended that all Airmar devices connected to the
NMEA 2000® bus will likewise also reply accordingly when receiving this PGN.