PROCool Electronic Panel
AKO-17635-1 / AKO-17635-2
Quick guide
Maintenance
Precautions
Description
Clean the surface of the unit with a soft cloth, water and detergent. Do not use abrasive
detergents, petrol, white spirits or solvents.
Using the equipment without following the manufacturer's instructions may affect the
device's safety requirements. To ensure that the device operates correctly, only probes
supplied by AKO should be used.
Between -40 ºC and +20 ºC, if the NTC probe is extended up to 1,000 m with minimum
0.5 mm² wire, the maximum deviation will be 0.25 ºC (Wire for probe extension ref.
AKO-15586)
IMPORTANT:
ŸThe function of the digital inputs depends on the configuration.
ŸThe recommended currents and powers are the maximum working currents
and powers.
Key function
Pressing it for 5 seconds activates the Stand-By mode. Pressing it for 2 seconds the unit
returns to the normal mode. In Stand-by mode, the unit performs no action and the
display only shows the m indicator along with the temperature.
During configuration, it exits the parameter without saving changes, returns to
previous level, or exits programming.
One short press* shows the non-displayed probe reading (see P8 parameter).
Pressing it for 5 seconds starts/stops the defrost.
During configuration, it allows you to scroll through the different levels, or when
setting a parameter, to change its value.
Pressing for 5 seconds accesses the quick configuration menu.
Pressing for 10 seconds accesses the advanced configuration menu.
During configuration, it allows you to scroll through the different levels, or when
setting a parameter, to change its value.
One short press* displays the current set point value (SP).
Pressing it for 5 seconds accesses change set point.
During configuration, it accesses the level shown on the display or, when setting a
parameter, it accepts the new value.
Messages
Quick configuration
The quick configuration menu allows the unit to be configured for the most common
applications. Press the key for 5 seconds to access it.
SP: Set point
It sets the coldroom's working temperature
d0: Defrost frequency
Time that must elapse between the starting of each defrost.
d1: Maximum defrost duration
The defrost will end after this time has elapsed since it started.
F3: Fan status during defrost
It defines the status of the fans during defrost.
Ÿ0= Stopped
Ÿ1= Running
A1: Maximum alarm probe 1
Defines the temperature at which the maximum alarm will be triggered. Only affects probe 1.
A2: Minimum alarm probe 1
Defines the temperature at which the minimum alarm will be triggered. Only affects probe 1.
P26: Stoppage owing to pump down
It defines whether this function is active
Ÿ0= Without pump down
Ÿ1= With pump down
SE
AKO
Stand-by active mode
Temperature
*Short press: Less than 5 seconds.
L5
Flashing 0: Access code (Password) request
You must enter the access code configured on L5 to execute the requested
function. See also parameter P2.
E1 / E2
Probe 1 or 2 faulty (open circuit, crossover or temperature outside the
probe limits; NTC: -50 To 99 ºC).
dEF
Indicates a defrost is underway. When the defrost process has finished, the
message will continue to be displayed during the time defined in
parameter d3.
AH
Alternating with temperature:
Maximum temperature in control probe alarm. Temperature set in A1 has
been reached.
AL
Alternating with temperature:
Minimum temperature in control probe alarm. Temperature set in A2 has
been reached.
AE
Alternating with temperature:
External alarm activated (by digital input).
AES
Alternating with temperature:
Severe external alarm activated (by digital input).
Adt
Alternating with temperature:
Defrost alarm time-out. Displayed when a defrost ends after the maximum
time elapsed as defined in parameter d1.
PAb
Alternating with temperature:
Door open alarm. Shown if the door remains open longer than specified in
parameter A12.
Pd
Alternating with temperature:
The maximum pump down stop time has been exceeded (P15)
LP
Alternating with temperature:
The maximum pump down start-up time has been exceeded (P14).
ASC
It indicates that a component in the compressor's safety chain has
triggered (compressor motor guard, thermistors or high pressure
controller).
Display
Stand-by key
Menu key
Set Point key
Defrost key
Alarm active
Compressor active (If P26=1)
Condenser fans
active
Defrosting in progress
Evaporator fans active
Solenoid active
ESC
SET
1
1763H502 Ed.01
GB

Other manuals for AKO PROCool AKO-17635-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AKO PROCool AKO-17635-2 and is the answer not in the manual?

AKO PROCool AKO-17635-2 Specifications

General IconGeneral
BrandAKO
ModelPROCool AKO-17635-2
CategoryControl Panel
LanguageEnglish

Related product manuals