Spectral Bandwidth | 5 nm |
---|---|
Data Acquisition Rate | Up to 100 Hz |
Wavelength Accuracy | ± 1 nm |
Temperature Range | 4 - 40 °C |
Weight | 5 kg |
Interface | Ethernet |
Path Length | 10 mm (standard), other path lengths available |
Flow Cell Volume | 8 µL |
Flow Rate Range | 0.001 - 100 mL/min |
Power Requirements | 100-240 V AC, 50-60 Hz |
Overview of the Monitor UV-900's features and capabilities for liquid chromatography.
Critical safety warnings and precautions for operating the Monitor UV-900, including electrical and UV hazards.
Instructions for unpacking the instrument and checking for shipping damage.
Guidelines for optimal placement and environmental conditions for instrument installation.
Step-by-step guide for correctly fitting the flow cell into the instrument.
Procedures for connecting signal output cables to external devices like recorders.
Instructions for establishing a computer network connection via UniNet cables.
Steps for safely connecting the instrument to a grounded mains power socket.
How to connect the fluidic tubing to the flow cell inlet and outlet.
Guidance on attaching the protective cover to the flow cell holder.
Procedures for powering the instrument on and off, including the selftest sequence.
How to navigate and select menus and options using the instrument's controls.
Explanation of the functions available in the main operating menu.
How to control the UV lamp status for measurement and energy saving.
How to display and interpret absorbance readings at different wavelengths.
Procedures for selecting and adjusting measurement wavelengths from 190 to 700 nm.
How to set the baseline absorbance to zero for accurate measurements.
Recommended procedures for storing the instrument and flow cell.
Configuration steps for outputting data to an external chart recorder.
How to use the moving average filter to reduce signal noise.
Guidance on replacing the flow cell for different sensitivity requirements.
How the instrument behaves and restarts after an interruption in power supply.
Schedule and actions for routine preventive maintenance of the instrument.
Procedure for cleaning the flow cell using chemical agents.
How to check critical instrument parameters like lamp intensity and runtime.
Detailed instructions for cleaning the flow cell and optical fibre interfaces.
Guidelines for cleaning the exterior of the instrument.
General advice and information for contacting technical support.
Common operational faults and their recommended corrective actions.
List of instrument error messages and their associated troubleshooting steps.
General description of the Monitor UV-900 and its connectors.
Details on the design, materials, and function of the available flow cells.
Explanation of the UV-absorption monitoring technology used by the instrument.
Details on the instrument's diagnostic and check functions.
Options for configuring instrument settings like language and unit number.
How to configure alarm functions and timers for automated operations.
Information on service-related displays and access codes.
A visual map of the instrument's menu structure and navigation paths.