19.4
Action URL
A02 allows you to set up specific HTTP URL commands that will be sent to the HTTP
server for the predefined actions. Relevant actions will be initiated if there occurs any
changes in the relay status, input status, PIN code, and RF card access for security
purpose. You can navigate to the Setting > Actions URL.
Akuvox Action URL:
11
Tamper Alarm
Triggered
$alarm status
Http://server ip/
tampertrigger=$alarm status
No
Event
Parameter format
Example
1
Make Call
$remote
Http://server ip/
Callnumber=$remote
2
Hang Up
$remote
Http://server ip/
Callnumber=$remote
3
Relay Triggered
$relay1status
Http://server ip/
relaytrigger=$relay1status
4
Relay Closed
$relay1status
Http://server ip/
relayclose=$relay1status
5
Input Triggered
$input1status
Http://server ip/
inputtrigger=$input1status

Other manuals for Akuvox A02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Akuvox A02 and is the answer not in the manual?

Akuvox A02 Specifications

General IconGeneral
InterfaceEthernet
Case design-
Event capacity100000
Number of users20000 user(s)
Card holders quantity20000
Maximum number of doors1 door(s)
Supported network protocolsIPv4, HTTP, HTTPS, FTP, SNMP, DNS, NTP, RTSP, RTP, TCP, UDP, ICMP, DHCP, ARP
Ethernet LAN data rates10, 100 Mbit/s
DC voltage range12 V
Power consumption600 mA
Ethernet LAN (RJ-45) ports1
Storage temperature (T-T)-30 - 70 °C